Interlogix Simon XT Tabletop Installation Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Painel de controlo Interlogix Simon XT Tabletop Installation Manual. Interlogix Simon XT Tabletop Installation Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Simon XT TableTop Control
Panel Installation Manual
P/N 466-2341 REV C OCT12
Vista de página 0
1 2 3 4 5 6 ... 85 86

Resumo do Conteúdo

Página 1 - Panel Installation Manual

Simon XT TableTop Control Panel Installation Manual P/N 466-2341 • REV C • OCT12

Página 2

Chapter 1: 4 Simon XT TableTop Control Panel Installation Manual Device Description Carbon monoxide (CO) alarm (60-652-95) The Learn Mode™ CO a

Página 3 - US:AAAEQ##TXXXX. The digits

Chapter 1: Simon XT TableTop Control Panel Installation Manual 5

Página 5 - Content

Simon XT TableTop Control Panel Installation Manual 7 Chapter 2 Planning This chapter provides information to help you plan your installation to r

Página 6 - Preface

Chapter 2: 8 Simon XT TableTop Control Panel Installation Manual Planning the installation This section describes system capabilities to help you ge

Página 7 - Introduction

Chapter 2: Simon XT TableTop Control Panel Installation Manual 9 Device Recommended sensor group Outdoor motion sensor 25 (chime only) Entry/ex

Página 8 - Product overview

Chapter 2: 10 Simon XT TableTop Control Panel Installation Manual Type Name/application Siren type Delay Restoral Supervisoryry Active in arming lev

Página 9 - System components

Chapter 2: Simon XT TableTop Control Panel Installation Manual 11 Type Name/application Siren type Delay Restoral Supervisoryry Active in arming l

Página 10 - Standard panel

Chapter 2: 12 Simon XT TableTop Control Panel Installation Manual Sensor # Device Sensor group Sensor name/location Notes 20 21 22 23

Página 11 - Chapter 1:

Chapter 2: Simon XT TableTop Control Panel Installation Manual 13 Figure 2: Cross-zone diagram Note: We do not recommend cross-zoning for exit/e

Página 12

Copyright © 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of Unite

Página 13 - Planning

Chapter 2: 14 Simon XT TableTop Control Panel Installation Manual Function Default Delete Range Access codea Installer settings User code 4 None Non

Página 14 - Planning the installation

Chapter 2: Simon XT TableTop Control Panel Installation Manual 15 Function Default Delete Range Access codea Installer settings DTMF On (Touchtone

Página 15 - Chapter 2:

Chapter 2: 16 Simon XT TableTop Control Panel Installation Manual Function Default Delete Range Access codea Installer settings Report communication

Página 16 - Chapter 2:

Chapter 2: Simon XT TableTop Control Panel Installation Manual 17 Function Default Delete Range Access codea Installer settings Touchpad options

Página 17

Chapter 2: 18 Simon XT TableTop Control Panel Installation Manual Function Default Delete Range Access codea Installer settings Speaker volume 8 8 1

Página 18

Chapter 2: Simon XT TableTop Control Panel Installation Manual 19 Function Default Delete Range Access codea Installer settings a This column tell

Página 20

Simon XT TableTop Control Panel Installation Manual 21 Chapter 3 Installation This section describes how to connect hardwired devices, and the AC po

Página 21

Chapter 3: 22 Simon XT TableTop Control Panel Installation Manual Panel connections The panel has three screw terminals, two telephone connections,

Página 22

Chapter 3: Simon XT TableTop Control Panel Installation Manual 23 Note: The total current available from HW1&2 DC Out is 250 mA at up to 120°

Página 23

FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC ru

Página 24

Chapter 3: 24 Simon XT TableTop Control Panel Installation Manual Connect hardwired reed switches to the panel using a 47 kohm resistor (not a 4.7 k

Página 25 - Emergency planning

Chapter 3: Simon XT TableTop Control Panel Installation Manual 25 2. Connect the four-conductor cable wires to the RJ31X. 3. Disconnect the gre

Página 26

Chapter 3: 26 Simon XT TableTop Control Panel Installation Manual 2. Connect the included phone cord to the panel LINE jack and the premises phone

Página 27 - Installation

Chapter 3: Simon XT TableTop Control Panel Installation Manual 27 Figure 8: Transformer connections Note: Do not plug in the transformer at this

Página 28 - Hardwired device terminals

Chapter 3: 28 Simon XT TableTop Control Panel Installation Manual Applying AC power To apply AC power, do the following: 1. Make sure the outlet is

Página 29 - Hardwired contacts

Chapter 3: Simon XT TableTop Control Panel Installation Manual 29 9 - Sirens with this setting sound alarms, arming level beeps, status beeps, an

Página 31 - Chapter 3:

Simon XT TableTop Control Panel Installation Manual 31 Chapter 4 Programming This chapter provides steps on how to program your unit. In this cha

Página 32 - Power transformer connection

Chapter 4: 32 Simon XT TableTop Control Panel Installation Manual Programming overview The control panel (Figure 9 below) provides the main processi

Página 33 - Powering up the panel

Chapter 4: Simon XT TableTop Control Panel Installation Manual 33 Control Description LCD display The LCD module has a 2 x 16 character array th

Página 35

Chapter 4: 34 Simon XT TableTop Control Panel Installation Manual of inactivity if no access code has been entered yet. After an access code has be

Página 36

Chapter 4: Simon XT TableTop Control Panel Installation Manual 35 Master code Phone #2 User code 1 Phone #3 User code 2 Phone #4 User code 3 Downl

Página 37 - Programming

Chapter 4: 36 Simon XT TableTop Control Panel Installation Manual Phone 3 reports Vox receiver gain Phone 4 reports Vox microphone gain Timers Vo

Página 38 - Programming overview

Chapter 4: Simon XT TableTop Control Panel Installation Manual 37 2. The display shows Enter code. Enter your code with numeric keys. Press Enter

Página 39 - Chapter 4:

Chapter 4: 38 Simon XT TableTop Control Panel Installation Manual 3. The system displays each entered access code digit as an asterisk. Press Enter

Página 40 - Menu navigation

Chapter 4: Simon XT TableTop Control Panel Installation Manual 39 Security Table 11 provides security option details. Table 11: Security Function

Página 41

Chapter 4: 40 Simon XT TableTop Control Panel Installation Manual Function Default Description Autoarm On Determines how long the system protests (

Página 42 - Set clock

Chapter 4: Simon XT TableTop Control Panel Installation Manual 41 Function Default Description Sup protest Off Determines whether the panel pro

Página 43 - System programming

Chapter 4: 42 Simon XT TableTop Control Panel Installation Manual Function Default Description Ring hang ring 1 Determines when the panel answers

Página 44 - Access codes

Chapter 4: Simon XT TableTop Control Panel Installation Manual 43 Sensors These instructions explain how to add (learn) sensors, touchpads, and

Página 45 - Security

Simon XT TableTop Control Panel Installation Manual i Content Preface#ii Chapter 1 Introduction#1 Product overview#2 Chapter 2 Planning#7 Planning

Página 46 - Chapter 4:

Chapter 4: 44 Simon XT TableTop Control Panel Installation Manual When learning sensors, the panel uses an ascending number sequence starting with

Página 47 - Phone options

Chapter 4: Simon XT TableTop Control Panel Installation Manual 45 5. The panel displays Sn ## Grp ## <Text>. Press the scroll buttons unt

Página 48

Chapter 4: 46 Simon XT TableTop Control Panel Installation Manual Function Default Description Closing reports Off Determines whether the panel s

Página 49 - Sensors

Chapter 4: Simon XT TableTop Control Panel Installation Manual 47 Function Default Description No usage Off Determines whether the panel sends

Página 50

Chapter 4: 48 Simon XT TableTop Control Panel Installation Manual Timers Table 18 below provides timer option details. Table 18: Timers Function Def

Página 51 - Reporting

Chapter 4: Simon XT TableTop Control Panel Installation Manual 49 Function Default Description RF time-out 12 hours Determines the time period t

Página 52

Chapter 4: 50 Simon XT TableTop Control Panel Installation Manual Function Default Description Panic alarms On Determines whether the panel panic

Página 53 - Restorals

Chapter 4: Simon XT TableTop Control Panel Installation Manual 51 Table 21: Siren options Function Default Description Piezo beeps On This option

Página 54

Chapter 4: 52 Simon XT TableTop Control Panel Installation Manual Function Default Description Alarm report verify Off This option determines wheth

Página 55 - Touchpad options

Chapter 4: Simon XT TableTop Control Panel Installation Manual 53 Table 23: Audio verification Function Default Description Audio mode Off 1 = Ins

Página 56 - Siren options

ii Simon XT TableTop Control Panel Installation Manual Preface This is the Simon XT TableTop Control Panel Installation Manual for model 600-1054-9

Página 57

Chapter 4: 54 Simon XT TableTop Control Panel Installation Manual To program the housecode, do the following: 1. Press the scroll buttons until t

Página 58 - Audio verification options

Chapter 4: Simon XT TableTop Control Panel Installation Manual 55 6. The panel displays On/off, which will be flashing. Press the scroll button

Página 59 - Light control (optional)

Chapter 4: 56 Simon XT TableTop Control Panel Installation Manual Table 24 below provides light control option details. Table 24: Light control Func

Página 60

Chapter 4: Simon XT TableTop Control Panel Installation Manual 57 6. Power up the panel with the battery and then the AC transformer. Note: The p

Página 62

Simon XT TableTop Control Panel Installation Manual 59 Chapter 5 Testing This section describes how to perform various test procedures. You should

Página 63

Chapter 5: 60 Simon XT TableTop Control Panel Installation Manual Control panel Test the panel by pressing the buttons as described in Table 26 bel

Página 64

Chapter 5: Simon XT TableTop Control Panel Installation Manual 61 Table 27: Arming levels Arming level Description Indication 0 Subdisarms (master

Página 65 - Testing

Chapter 5: 62 Simon XT TableTop Control Panel Installation Manual Table 28: Sensor tripping instructions Sensor Do this Door/window Open the secure

Página 66 - Control panel

Chapter 5: Simon XT TableTop Control Panel Installation Manual 63 Type of sensor Number of beeps Wireless smoke and heat sensors 7 to 8 Wireless e

Página 67 - Sensor testing

Simon XT TableTop Control Panel Installation Manual 1 Chapter 1 Introduction Summary This chapter provides an overview of the system and an outline

Página 68 - Chapter 5:

Chapter 5: 64 Simon XT TableTop Control Panel Installation Manual 3. If the known-good sensor functions, contact UTC Fire and Security for repair

Página 69 - Sn test fail or aborted

Chapter 5: Simon XT TableTop Control Panel Installation Manual 65 System Function Phone command Specific light off # – <unit_num>. All light

Página 70 - Phone communication

Chapter 5: 66 Simon XT TableTop Control Panel Installation Manual Arm or disarm from Reports as user Access codes 1 to 8 47 to 54 Duress code 55 Tw

Página 71 - Chapter 5:

Chapter 5: Simon XT TableTop Control Panel Installation Manual 67 4. Press * and the panel voice identifies the alarm. If there is more than one

Página 72 - Voice event notification

Chapter 5: 68 Simon XT TableTop Control Panel Installation Manual X10 siren and lamp module functions All sirens turn off when the system is disarm

Página 73 - X10 operation

Simon XT TableTop Control Panel Installation Manual 69 Chapter 6 Troubleshoot and support This chapter provides information to help you troubleshoo

Página 74

Chapter 6: 70 Simon XT TableTop Control Panel Installation Manual Troubleshooting This section provides information to help you diagnose and solve v

Página 75 - Troubleshoot and support

Chapter 6: Simon XT TableTop Control Panel Installation Manual 71 Latchkey is not enabled. Enable latchkey by pressing Motions twice. The phone

Página 76 - Troubleshooting

Chapter 6: 72 Simon XT TableTop Control Panel Installation Manual Unplug nearby equipment that may be causing interference (light dimmer switches,

Página 77 - Chapter 6:

Simon XT TableTop Control Panel Installation Manual 73 Appendix A Specifications and tables This appendix provides lists of sensor names and a quick

Página 78 - Contacting us

Chapter 1: 2 Simon XT TableTop Control Panel Installation Manual Product overview This security system can be used as a fire warning system, an int

Página 79 - Specifications and tables

Appendix A: 74 Simon XT TableTop Control Panel Installation Manual Specifications Table 35: Simon XT TableTop Control Panel specifications Requireme

Página 80 - SIA system requirements

Appendix A: Simon XT TableTop Control Panel Installation Manual 75 Function Programming page reference Default setting Required setting Autoarm T

Página 81 - Appendix A:

Appendix A: 76 Simon XT TableTop Control Panel Installation Manual Central station reporting The panel has been tested with the following central s

Página 82 - Sensor names

Appendix A: Simon XT TableTop Control Panel Installation Manual 77 # Phrase # Phrase # Phrase 130 Family room 041 Module 142 Fire 024 Office

Página 83

Appendix A: 78 Simon XT TableTop Control Panel Installation Manual # Phrase # Phrase # Phrase 028 Garage 077 8 126 x 029 Special chime 078 9 127 y

Página 84 - Appendix A:

Appendix A: Simon XT TableTop Control Panel Installation Manual 79 :Simon XT TableTop System quick reference

Página 86

Chapter 1: Simon XT TableTop Control Panel Installation Manual 3 System components The system can monitor up to 40 sensors and may use any of the

Comentários a estes Manuais

Sem comentários