Video Switcher Commands
Table 16. Samples of outgoing commands from the ACU
Sent to: Format Description Command
American Dynamics
Video switcher
ASCII Alarm 001Ea<cr> Contact 001
Cancel 001Ia<cr> Contact 001
Vicon
Video switcher
ASCII Alarm <01h>u0001S<cr> Contact 001
Cancel <01h>u0001R<cr> Contact 001
Javelin
Win Quest switcher
HEX Alarm “FF” “06” “86” “04” “00” “01” “02” “92” Contact 001
Cancel “FF” “06” “86” “04” “00” “01” “03” “93” Contact 001
Javelin
Quest Plus switcher
ASCII Alarm 0001Ea Contact 001
Cancel 0001Ia Contact 001
Kalatel
Video switcher
ASCII Put camera 001 in alarm 00[001~
Reset camera 001 from alarm 00\001~
Phillips/Burle
Video switcher
ASCII Alarm +ALARM 1<cr> Contact 001
Cancel -ALARM 1<cr> Contact 001
Phillips/Burle
Var Speed
Video switcher
ASCII Alarm +ALARM 1<cr> Contact 001
Cancel -ALARM 1<cr> Contact 001
Pelco
Video switcher
ASCII Alarm 001Ia Contact 001
Cancel 001Ea Contact 001
Panasonic
Video switcher
HEXI Alarm “02 43 4d 44 3a 48 41 28 38 30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 29 03” Contact 001
Cancel “02 43 4d 44 3a 48 41 28 30 30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 29 03” Contact 001
Elbex
CCTV switcher
ASCII Alarm
Cancel
Pelco CM6800
CCTV switcher
ASCII Alarm 1 active
Alarm 128 active
1Je
128Je
Alarm 1 secure
Alarm 128 secure
1~Je
128~Je
Ultrak
CCTV switcher
ASCII Alarm 1 active
Alarm 128 active
#0[A1=T]<cr>
#0[A128=T]<cr>
Alarm 1 secure
Alarm 128 secure
#0[A1=F]<cr>
#0[A128=F]<cr>