Interlogix Monitor XL Advanced Installation Guide Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 76
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
6 Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
S00200 Keypad Selections (left to right on keypad screen)
Default Name Selections Description
0
Operation Mode Enter from right to left.
0 - Standard version
1- European with modem support
2- UK (DD243) (ACPO)
3-7 – for future extension
(UK ACPO = 2)
03
Feature Set
1-14 from the following table. This setting determines the system
capacity.
Feature Set Levels and Panel Capacities:
Feature
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Users
20 20 100 100
300 1,000
1,000 1,000 2,000 4,000 10,000 10,000 20,000 20,000 20,000 64,000 64,000
Doors
0 16 0 16 4 16
16 32 32 32 32 32 32 32 32 32 32
Schedule
50 50 50 50 50 50 100 100 100 100 250 250 250 250 250 250 250
A
uthority
30 30 30 30 30 30 100 100 100 100 500 500 500 1,000 1,000 1,000 1,000
Profile
60 60 60 60 60 60 200 200 200 200 750 750 1,000 1,000 1,000 1,000 1,000
User Edit
10 10 10 10 10 10 50 50 50 50 750 750 1,000 1,000 1,000 1,000 1,000
Floor
A
uthority
0 0 0 0 0 0 0 50 50 50 100 100 100 100 100 100 100
Point
256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256
Outputs
128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128
A
rea
16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
Log
1,024 1,024 1,024 1,024 1,024 1,024 2,048 2,048 2,048 2,048 8,192 8,192 8,192 16,364 16,364 65,536
32,768
(ISM),
16,364
(xL)
Module*
24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24
Custom
Point
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Pseudo
Point
16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
Holiday
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
Suite
Security
0 0 0 0 0 0 0 60 60 60 60 60 60 60 60 60 60
Floor
0 0 0 0 0 0 0 124 124 124 124 124 124 124 124 124 124
* Plus capacity for one temporary service LCD keypad for connecting to the module bus at the main controller.
Additional RAM must be added with Feature Set 4 and greater. The “Feature Expansion Board” must be added to the
system.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 75 76

Comentários a estes Manuais

Sem comentários